2017年3月27日星期一

The face of the hot summer, the Electric and Manual Straddle Stacker how to survive it? In order to ensure the battery life, we charge and use to pay attention to what matters?
1, the charging circuit and the first to be fully out of the loop and chopper, because the chopper and the charger will interact with each other, but also pay special attention to the battery to the electronic control of the alignment to be balanced and as short as possible The
2, charging room and the battery room must be pre-set between the rechargeable cable. At the same time, in order to facilitate maintenance and repair, each charger to have an independent power control switch, charging room but also configure the corresponding power distribution cabinet;
3, if the charging process, the electrolyte temperature exceeds 55 ℃, should immediately try to cool, if the temperature still does not decline, should be suspended charging until the temperature drops and then continue to charge;
4, do not charge when the charger and battery can not be placed together, so the charging room and the battery storage battery room must be separated. Battery room but also row acid fog, ventilation and other equipment;
5, the company should be prepared to put a solution and the new dry batteries and other dangerous goods warehouse, but also a place of tools, connectors, fasteners and other work supplies of the Treasury;
6, if you need to replace or repair the battery, must be specially trained personnel to replace and repair. But also regularly check the wiring is loose or damaged, and timely adjustment or replacement.

2017年3月20日星期一

High Lifting stacker used ordinary battery should be a monthly water, the other types of batteries to the water consumption, regular to add distilled water. On the temporary use of the battery can be delayed for several months and then pay.
To the battery water, the amount should be added to the electricity. If some of the battery appears to drop the liquid surface faster, frequent water, to check the regulator on the car limit the voltage is too high. Too high will appear overcharge, water consumption, evaporation fast, this situation can be resolved by adjusting the limit voltage. If the individual battery down fast, to check whether the phenomenon of short circuit. In addition, but also depends on the battery slot with or without cracks, electrolyte leakage, according to the truth to judge and then line treatment.
If the Electric counterbalance stacker battery dumps, the electrolyte flows out of the lead, so that the electrolyte can be replenished. The electrolyte can not be added to the battery. Supplementary electric forklift electrolyte to be the original electrolyte density to be added. Sometimes electric handling forklift can not start, many people will think that is due to lack of electricity, often to the battery with electrolyte, the result is counterproductive, greatly shorten the battery life.

2017年3月13日星期一

Mechanical equipment in the long-term use after the failure is inevitable, for Semi Electric Stackers is no exception, it may also be used when the failure of a certain, what is it? Common power system failure mainly in the absence of Charging, charging voltage is too low and the charging voltage is too high.
1, no charge
Symptom: electric stacker car engine normal work charge indicator light or ammeter indicating negative direction, indicating that the generator does not generate electricity, the battery is not charging.
Failure causes: generator failure, regulator failure or electrical line fault.
2, Electric Straddle Stackers car charging voltage is too low
Symptom: During the operation of the engine, the charging indicator flashes or the ammeter swings around zero. The voltage value at both ends of the battery or generator is measured using the DC voltage of the multimeter. If the voltage is lower than the standard value, the charging voltage is too low.
Failure reasons: regulator operating voltage offset or faulty, transmission belt is too loose, the generator stator, rectifier, rotor and other components are faulty.
3, the charging voltage is too high
Symptom: the stack of high-car engine work process bulb easy to burn, battery electrolyte consumption too fast, the use of multimeter DC voltage file to measure the voltage across the battery or generator, such as higher than the standard value, then the charge voltage is too high.
Failure reason: regulator operating voltage is out of order or faulty.
People in the use of electric forklift may encounter electric forklift such a failure, people in the event of failure can follow the above reasons for timely investigation, if they can not solve the professional maintenance personnel can come to solve.

2017年3月6日星期一

As we all know, the degree of hydraulic oil cleanliness is the life of the hydraulic system. Hydraulic system has many precision even, and some damping holes or gaps and so on. If the solid impurity invasion will result in precision even pieces of injury, hairpin, oil blockage, etc., endangering the safe operation of the hydraulic system. General solid material invasion path are: hydraulic oil is not clean; refueling tool is dirty; refueling and maintenance, maintenance careless; hydraulic components desquamation and so on.  Electric fork over stacker to remind you forklift driving friends can prevent the following aspects of solid impurities invasion system:
1, when the oil must be filtered oil, refueling tools should be reliable and clean. It is not possible to remove the filter at the filling point of the hydraulic tank in order to increase the fueling speed. Refueling personnel must use clean gloves and work clothes.
2, second-hand forklift maintenance when the removal of hydraulic fuel tank cover, filter cover, detection hole, hydraulic tubing and other parts of the hydraulic system to avoid dust when exposed to the oil, the demolition of the site must be thoroughly cleaned before opening. If you remove the oil tank cover, remove the soil around the fuel tank cover, remove the oil tank cover after the removal of residual parts of the debris (not rinse with water to avoid water into the Hand Pallet Trucks with scale), to confirm the cleaning before opening the fuel tank cover. If you need to use the wipe material and hammer, you should choose not to wear fiber impurities and rubbing the material attached to the rubber hammer. Hydraulic components, hydraulic hose to be carefully cleaned, with high pressure air dry after assembly. Selection of packaging integrity of the genuine filter (if the packaging is damaged, although the filter is intact, it may be unclean). Oil cleaning at the same time to clean the filter, install the filter before the application of scrubbing material carefully remove the filter shell internal dirt.
3, the hydraulic system of cleaning oil must be used with the system with the same hydraulic oil, oil temperature between 45 ~ 80 ℃, with a large flow as much as possible to take away the impurities in the system. Hydraulic system to be cleaned more than three times, after each wash when the oil heat to release all of the system. After cleaning and then clean the filter, replace the new filter and add new oil.