High Lifting stacker used ordinary battery should be a monthly water, the other types of batteries to the water consumption, regular to add distilled water. On the temporary use of the battery can be delayed for several months and then pay.
To the battery water, the amount should be added to the electricity. If some of the battery appears to drop the liquid surface faster, frequent water, to check the regulator on the car limit the voltage is too high. Too high will appear overcharge, water consumption, evaporation fast, this situation can be resolved by adjusting the limit voltage. If the individual battery down fast, to check whether the phenomenon of short circuit. In addition, but also depends on the battery slot with or without cracks, electrolyte leakage, according to the truth to judge and then line treatment.
If the Electric counterbalance stacker battery dumps, the electrolyte flows out of the lead, so that the electrolyte can be replenished. The electrolyte can not be added to the battery. Supplementary electric forklift electrolyte to be the original electrolyte density to be added. Sometimes electric handling forklift can not start, many people will think that is due to lack of electricity, often to the battery with electrolyte, the result is counterproductive, greatly shorten the battery life.